Anti-CO2 and Anti-CO2/H2S Corrosion Casing and Tubing
With the increasingly harsh conditions of oil and gas wells, the corrosive environment faced by OCTG is becoming much more severe. Accidents caused by the above-mentioned corrosion failure not only caused huge economic losses, but also had serious social consequences.
Based on lots of experimental studies, Glory Tube develops casing and tubing with favorable anti-CO
2 and anti-CO
2/H
2S corrosion performance.
Uses
Used for oil and gas wells containing CO
2, H
2S corrosive media.
Names
Naming rule: GL+ Strength + "–*Cr"; GL+ Strength + Anti-H
2S + "–*Cr"
Meanings
GL - Glory Tube Non-API series
Strength - Specified minimum yield strength (the unit is KSI and trimmed to multiples of 5)
S - Anti-H
2S SS - High anti-H
2S
*Cr - Anti-CO
2 corrosion; * is Cr content
CO2 Corrosion Resistance Test
Corrosion resistance test is carried out according to the service environment.
Standard Test Conditions
Test solution: 3.5% NaCl
Carbon dioxide partial pressure: 2.5MPa;
Temperature: 60℃
Time: 10 days
The dynamic or static autoclave corrosion resistance test is carried out according to the above conditions.
Anti-CO2 and Anti-H2S Corrosion Resistance of Casing and Tubing
Types |
Grade |
Anti-CO2 Corrosion
Resistance |
Anti-H2S Corrosion
Resistance |
1Cr |
GL55-1Cr
GL80-1Cr |
Corrosion resistance is doubled compared to conventional materials in moderately corrosive media |
- |
3Cr anti-CO2/H2S Corrosion |
GL80SS-3Cr
GL90SS-3Cr
GL95SS-3Cr |
Corrosion resistance increases by 2 times compared to conventional materials in moderate corrosive media |
NACE TM 0177 A
SYMS*90%
720 Hours |
GL80S-3Cr
GL90-3Cr
GL95S-3Cr
GL110S-3Cr |
NACE TM 0177 A
SYMS*80%
720 Hours |
3Cr anti-CO2 Corrosion |
GL80-9Cr
GL90-9Cr
GL95-3Cr
GL110-3Cr |
- |
9Cr anti-CO2 Corrosion |
GL80-9Cr
GL90-9Cr |
Corrosion res stance test is carried out according to the service environment. |
- |
13Cr anti-CO2 Corrosion |
GL80-13Cr
GL110-13Cr |
- |